Bharat Surgical Co. manufactures and supplies selected urology instruments and endoscopic system components for hospitals, urologists, surgical centres, dealers, distributors and institutional buyers. Established in 1975 and based in Mumbai, India, the company accepts requirements for cystoscopy, TURP, PCNL, ureteroscopy, working elements, sheaths, obturators, forceps, bridges, connectors and stone-management instruments, subject to current product confirmation.
A urology instrument should not be selected by name or photograph alone. Share the procedure-specific instrument group, telescope or scope make and model, diameter or French size, working length, working channel, sheath, bridge, obturator, working element, electrode or loop, energy platform, connection, quantity and destination for an order-specific quotation.
Many cystoscopy, resectoscopy, PCNL and ureteroscopy components form part of a modular system. A telescope, sheath, obturator, bridge, working element, electrode, cable, connector or forceps may look similar to another component while differing in diameter, length, locking interface, working channel, irrigation arrangement or equipment compatibility.
This page helps buyers identify the correct category and prepare a complete request for quotation. The responsible clinical user and biomedical team should approve the required system. Bharat Surgical must confirm the accepted specification, supplied condition, compatibility evidence, documentation, commercial terms and delivery commitment in writing for the exact configuration.
Cystoscopy sheaths, working elements, loops, and PCNL/ureteroscopy access Dilators.

Diagnostic and operative sheaths, bridges, obturators, and optical biopsy forceps. Specify French sizes, locking connections, and channel requirements.
Explore Range
Resectoscope sets, inner and outer sheaths, active/passive working elements, loop electrodes, and compatible cables. Confirm generator make and model details.
Explore Range
Active, passive, single-stem, double-stem, monopolar, bipolar-related and laser TURP working elements for compatible resectoscope systems.
Explore Range
Nephroscopy sheaths, access dilators, stone punch, and accessories for percutaneous nephrolithotomy procedures.
Explore Range
Ureteroscopy handles, dilators, stone extractors, and compatible endourology accessories for clinics and hospitals.
Explore Range
Reusable stainless steel Batuchi sheaths in 2.9 mm and 4 mm configurations for compatible diagnostic hysteroscopy systems.
Explore Range
TURP 26 Fr inner outer sheaths manufactured from SS 304 for continuous flow and compatible resectoscope systems.
Explore Range
Reusable stainless steel VIU Sheaths (21 Fr) for compatible optical urethrotomy and stricture treatment systems.
Explore Range
Stainless steel SS 304 cystoscopy sheaths with obturators, available in 15.3 Fr to 25 Fr diagnostic or operative sizes.
Explore Range
Hysteroscopy diagnostic sheaths in 2.9 mm and 4 mm Stryker-type SS 304 configurations for diagnostic visualization.
Explore Range
Hysteroscopy operative sheaths in 2.9 mm and 4 mm clickline configurations with working channels for surgical access.
Explore Range
Reusable visual obturators for compatible urology sheaths and rigid telescopes to ensure safe urethral entry.
Explore Range
Reusable stainless steel Litho sheaths and matching obturators for compatible urology and lithotripsy systems.
Explore Range
Reusable biopsy forceps for compatible urological endoscopic systems. Available in required channel sizes and patterns.
Explore Range
Urology bridges and connectors, including Y-connectors, telescoping adapters, big-bore, and Luer Lock interfaces.
Explore Range
Optical stone crushing forceps and bladder stone punch sets in stainless steel and brass configurations.
Explore RangeProvide one specification row for every required component. For a set, list each included item separately.
| Specification Field | Information to Confirm |
|---|---|
| Product identity | Category, exact product or set name, Bharat Surgical code if known, approved reference, previous order and whether the request is for a complete system or replacement component. |
| System & procedure | Cystoscopy, TURP/resectoscopy, PCNL, ureteroscopy, VIU, lithotripsy or other approved context; monopolar or bipolar where relevant. |
| Scope or telescope | Make, model, code, rigid or flexible type, diameter, working length, direction of view, field or channel details and photographs of labels or interfaces. |
| Dimensions | French size, outer and inner diameter, working and overall length, working-channel size, jaw or distal dimensions and critical tolerances. |
| Sheath and access | Single or double sheath, diagnostic or operative type, continuous-flow or other irrigation, lock, taps, distal profile, obturator and dilator requirements. |
| Working element | Active or passive action, control and movement, telescope/sheath interface, electrode arrest or connection and compatible system. |
| Electrode or loop | Monopolar or bipolar, loop or electrode pattern, working length, connection, cable and generator make/model; do not assume cross-system interchangeability. |
| Bridge & connection | Number and size of channels, telescope/sheath connection, irrigation port, cable, adaptor and every mating component. |
| Supplied condition | Reusable or single-use expectation, sterile or non-sterile expectation, packaging and available cleaning, handling or reprocessing information. |
We serve clinical, biomedical, and commercial channels for endourology and TURP instruments.
Submit single replacement components, complete resectoscopy sets, PCNL schedules, or annual B2B tenders. Include telescope diameters, lengths, and locking interfaces.
Specify resectoscope active/passive preferences, loop thickness, cystoscope angles (0°/30°/70°), and sheath continuous-flow features. Professional clinical suitability is required.
Verify telescope-sheath locks, cable-socket alignment, insulation integrity, and autoclave cycle limits. Do not assume cross-compatibility without written confirmation.
Request our current approved urology catalogues. Submit target buyer segments, sizes, quantities, shipping terms, and document expectations.
Order-specific checks may include review of the accepted description, dimensions, finish, visible workmanship, movement, assembly, fit or connection, and channel patency. The inspection scope must match the component.
ISO Statement: Bharat Surgical's quality-management system is certified to ISO 13485:2016. CE, FDA, and performance claims require current evidence covering the exact supplied product.
Do not assume reusable, single-use, autoclavable, sterile-packed or ready-for-use status from the product name. The quotation, label and product documentation should identify the supplied condition.
Healthcare facilities remain responsible for following the applicable manufacturer instructions. Instruments with channel blockage, leakage, corrosion, or damaged insulation should be segregated.
Technical and B2B procurement answers for cystoscopy, resectoscopy, and sheaths.
The approved range covers cystoscopy sheaths, bridges, obturators, optical biopsy forceps, working elements, loops, PCNL access dilators, and ureteroscopy instruments. Active models, set compositions, and availability must be verified in writing.
Bharat Surgical's verified profiles describe the Mumbai business as both a manufacturer and supplier. The status may vary by item, so the quotation should identify whether the required component is manufactured, supplied, customized or available only after evaluation.
Bharat Surgical is based in Malad West, Mumbai, Maharashtra, India. Supply, export and service feasibility depend on the product, quantity, destination and accepted terms.
The verified company profile states that Bharat Surgical was established in 1975. We use the fixed establishment year rather than an automatically changing experience claim.
Yes. Send the exact telescope or scope, sheath, obturator, bridge, working channel, forceps and system details so availability and compatibility can be confirmed.
Provide the sheath type, French size or diameter, working length, diagnostic or operative requirement, single or double channel, irrigation arrangement, lock, compatible telescope, obturator, bridge, quantity and supplied condition.
They should not be treated as interchangeable labels. The channel configuration, size, irrigation, compatible instruments and intended system may differ. Confirm the exact product code and mating components for the required setup.
TURP surgery instruments, working elements, TURP loops and Bi-TURP sets appear in the approved sitemap. The complete system, component list and current availability must be confirmed before quotation or publication.
State active or passive action, telescope and sheath interfaces, monopolar or bipolar configuration, compatible electrode, cable, connector and generator make/model. Selection should be approved as a complete system.
No interchangeability should be assumed. The working element, electrode or loop, sheath, cable, connector and generator must be identified and confirmed together.
PCNL Instruments is planned as a separate category in the approved sitemap, but the current public catalogue does not clearly evidence the complete PCNL range. Management should confirm active products, set composition and specifications before publication or quotation.
Ureteroscopy Instruments is an approved category with planned URS Handle and URS Push Handle child pages. Current models, compatible shafts or inserts and supplied components must be verified before publication.
Share the product or set name, procedure group, scope or telescope make/model, French size or diameter, working length, working channel, sheath, obturator, bridge, working element, electrode or loop, energy platform, connection, supplied-condition requirement, quantity, destination, required date and documents.