Bharat Surgical manufactures and supplies reusable 21 Fr VIU sheaths for hospitals, urology centres, medical colleges, surgical-instrument dealers and international distributors. Also known as an optical urethrotomy sheath, the VIU sheath forms part of a compatible visual internal urethrotomy instrument system. A 21 Fr sheath must be matched with the exact telescope, working element, visual obturator, blade or knife carrier and irrigation components. The size alone does not establish system compatibility.
A VIU sheath is the outer access component of a compatible optical internal urethrotomy instrument system. The abbreviation VIU is commonly used for Visual Internal Urethrotomy. The instrument may also be described as an OIU sheath, referring to Optical Internal Urethrotomy.
The sheath houses or connects with the compatible optical and working components required by the specified system. It is not a complete urethrotomy set by itself.
A 21 Fr sheath must be matched with the exact telescope, working element, visual obturator, blade or knife carrier and irrigation components. The size alone does not establish system compatibility.
Bharat Surgical lists VIU Sheath 21 Fr as a dedicated Level 3 category within its urology instrument range. View the published VIU Sheath 21 Fr category. The related Bharat Surgical product page identifies the instrument as:
| Published specification | Details |
|---|---|
| Product type | Optical urethrotomy sheath / VIU sheath |
| Material | Stainless steel |
| Usability | Reusable |
| Brand | Bharat Surgical |
| Application | Hospital |
View Bharat Surgical’s optical urethrotomy sheath. The category confirms the 21 Fr size, while the related product page confirms the general product type, stainless-steel construction and reusable classification. The exact working length, telescope diameter, viewing angle, lock, blade interface and supplied components must still be confirmed in the quotation.
The French scale is used to describe the nominal outside diameter of tubular medical instruments.
Nominal diameter in millimetres = French size ÷ 3
Therefore: 21 Fr ÷ 3 = approximately 7.0 mm.
The 7.0 mm figure is a mathematical French-scale conversion. It should not replace the manufacturer’s dimensional drawing because actual profile, tolerance, wall thickness and internal working space remain product-specific.
The following terms may appear in enquiries:
These terms may describe similar product categories, but they do not prove that components from different systems are interchangeable. Always identify the exact manufacturer, model and interface.
| Component | Role within the system | Details to confirm |
|---|---|---|
| 21 Fr VIU sheath | Provides the outer access and working structure | Size, length, profile and lock |
| Obturator | Fits the specified sheath | Standard or visual type, length and tip |
| Rigid telescope | Provides endoscopic visualisation | Diameter, working length and viewing angle |
| Working element | Controls the compatible blade or knife carrier | Active/passive mechanism and interface |
| Urethrotomy blade | Model-specific cutting component | Shape, length and working-element compatibility |
| Blade carrier | Holds the compatible blade | Lock, travel and working element |
| Irrigation connection | Connects the approved fluid arrangement | Port, stopcock and tubing interface |
| Light cable | Connects the telescope to the light source | Connector on both ends |
| Camera coupler | Connects the telescope to the camera | Eyepiece and camera-head compatibility |
| Sterilisation tray | Holds compatible components during processing | Instrument layout and IFU compatibility |
The supplied package may contain only the sheath. Confirm every component included in the quotation.
| Selection point | VIU sheath only | Complete VIU set |
|---|---|---|
| Components | Sheath, or sheath with specified accessory | Sheath plus compatible optical and working components |
| Telescope | Normally not included unless specified | May be included |
| Working element | Not automatically included | May be included |
| Blade or knife | Not automatically included | May be included or separately supplied |
| Light cable | Separate unless specified | May be included |
| Procurement priority | Existing system compatibility | Complete BOQ and system compatibility |
Buyers should state clearly whether they need only a replacement 21 Fr sheath or a configured VIU instrument set.
| Feature | VIU sheath | Cystoscope sheath |
|---|---|---|
| Instrument-system role | Part of an optical urethrotomy system | Part of a cystoscopy system |
| Working element | Designed around a compatible urethrotomy component | Uses a bridge and compatible cystoscopy instruments |
| Blade compatibility | System-specific urethrotomy blade or carrier | Not implied |
| Telescope compatibility | VIU-system specific | Cystoscope-system specific |
| Interchangeability | Not assumed | Not assumed |
A 21 Fr cystoscope sheath should not be substituted for a 21 Fr VIU sheath solely because the French size is the same.
A VIU sheath and visual obturator are different components:
Bharat Surgical lists Visual Obturator separately, confirming that it should not automatically be treated as part of every VIU sheath quotation.
Before ordering a 21 Fr VIU sheath, confirm:
Two telescopes with the same diameter may differ in length, angle and proximal interface.
The working element controls the movement of the compatible blade or knife carrier. Depending on the system, it may have an active or passive operating mechanism. Confirm:
A TURP working element should not be assumed to fit a VIU sheath unless that exact system compatibility is documented.
Urethrotomy blades may differ in:
The clinical selection and use of a blade are the responsibility of qualified healthcare professionals. Bharat Surgical’s public VIU sheath pages do not currently specify an included blade, so the page must not imply that one is supplied.
Depending on the model, a VIU sheath may include:
Before ordering, confirm number of ports, port position, stopcock design, thread type, tubing connection, required seals, cleaning access, and whether irrigation accessories are included. Do not assume that a connector from a cystoscope or resectoscope will fit the VIU sheath.
Bharat Surgical’s related optical urethrotomy sheath page specifies stainless-steel construction. The exact stainless-steel grade is not stated and should be confirmed when required. Buyers should evaluate:
Material certificates, passivation information or surface-finish documentation should be requested where required by a hospital tender or importing authority.
| Compatibility point | Information required |
|---|---|
| Sheath | 21 Fr size, working length, profile and lock |
| Telescope | Manufacturer, model, diameter, length and viewing angle |
| Obturator | Standard or visual, size, length and interface |
| Working element | Manufacturer, active/passive type and catalogue number |
| Blade or knife | Shape, carrier and working-element compatibility |
| Irrigation | Port, stopcock and connector |
| Camera system | Coupler and telescope-eyepiece compatibility |
| Light source | Light cable connectors |
| Reprocessing | Validated IFU for each reusable component |
| Replacement request | Existing markings, dimensions and photographs |
| Documentation | Tender and destination-country requirements |
Bharat Surgical’s related product page describes the optical urethrotomy sheath as both reusable and sterile. These terms refer to different matters:
Because the public page does not provide packaging, sterilisation method or shelf-life details, sterile supply status must be verified in the final quotation. Do not assume that every reusable VIU sheath is delivered sterile.
Steam sterilisation should be used only when the manufacturer’s IFU validates it for the exact sheath and supplied components. Confirm:
The telescope, working element and blade may have separate reprocessing instructions.
Reusable VIU sheaths have narrow channels, locks, ports and detachable components that require careful reprocessing. The US FDA describes reprocessing as a multistep process involving cleaning followed by appropriate disinfection or sterilisation. Read the FDA’s reusable-device reprocessing information.
Cleaning must precede sterilisation or high-level disinfection because retained soil can interfere with the process. See the CDC disinfection and sterilisation guideline. The product-specific IFU and applicable local regulations always take priority.
| Component | Suggested quantity |
|---|---|
| VIU sheath 21 Fr | 1 |
| Matching obturator | 1 |
| Compatible rigid telescope | 1 |
| Compatible working element | 1 |
| Approved blade carrier | 1 |
| Compatible urethrotomy blades | As required |
| Irrigation stopcock and connector | 1 set |
| Light cable | 1 |
| Camera coupler | 1 |
| Cleaning accessories specified by the IFU | 1 set |
| Sterilisation tray or container | 1 |
This BOQ is a procurement template, not a clinical setup or procedural guide. The final configuration must be approved by qualified urology, biomedical and sterile-services personnel.
Before requesting a quotation, determine:
For Hospitals: Hospitals and urology centres may request new 21 Fr VIU sheaths, replacement VIU sheaths, matching obturators, compatible telescopes, working elements, blade carriers, spare stopcocks and seals, sterilisation trays, biomedical compatibility review, and tender BOQ assistance. The existing system information should be provided before purchasing replacement components.
For Medical Colleges: Medical colleges and teaching hospitals may require complete VIU instrument configurations for authorised clinical use, demonstration, simulation or skills training. The intended environment should be specified so that the suitable component list, documentation and reprocessing requirements can be discussed.
Bharat Surgical accepts enquiries from:
Dealers may request individual sheaths, complete sets, mixed urology-instrument orders, bulk quantities, export packaging and available technical documents. Destination-country registration, labelling and import requirements must be confirmed.
Exact working length, stainless-steel grade, telescope compatibility, supplied accessories, reusable status and sterile supply condition must be verified against the final quotation and product documentation.
Technical, compatibility, ordering and reprocessing answers for the Bharat Surgical VIU Sheath 21 Fr range.
A VIU sheath is an outer instrument component used as part of a compatible visual internal urethrotomy system.
VIU commonly means Visual Internal Urethrotomy.
OIU commonly means Optical Internal Urethrotomy. VIU and OIU may describe similar instrument categories.
Bharat Surgical lists VIU Sheath 21 Fr as a dedicated urology instrument category.
The mathematical French-scale conversion is approximately 7.0 mm.
Not necessarily. Actual profile, tolerance, wall thickness and connector dimensions are product-specific.
Bharat Surgical’s related optical urethrotomy sheath page specifies stainless-steel construction.
The current public page does not state the exact grade. Request it in the technical quotation if required.
Bharat Surgical’s related product page describes the optical urethrotomy sheath as reusable.
The public page uses the term sterile but does not provide packaging or shelf-life details. Sterile supply status must be confirmed in the quotation.
No. A complete system may also require a telescope, obturator, working element, blade carrier and other accessories.
Not unless it is specifically listed in the quotation or set contents.
No. Telescope diameter, length, viewing angle and locking interface must match.
The telescope must align correctly with the sheath, working element and distal operating field.
It may be included or quoted separately. Confirm the package contents.
Only when the exact visual obturator is compatible with the selected 21 Fr sheath and telescope.
No. A visual obturator accommodates a telescope, while a standard obturator generally does not.
No. They belong to different instrument systems and have different working-component interfaces.
Not unless that exact compatibility is documented by the applicable manufacturer.
It is the compatible mechanism that controls the model-specific blade or knife carrier.
Not automatically. The sheath, telescope, carrier and instrument system must match the selected working element.
The public VIU sheath page does not confirm an included blade. It should be listed separately in the quotation.
No. Blade shape, carrier, length and working-element interface must be compatible.
The exact port and stopcock configuration must be confirmed for the selected model.
Availability depends on the sheath model. Submit the existing reference and photographs.
Only if the product-specific IFU validates steam sterilisation for the exact sheath and components.
Follow the IFU for brushing, flushing, rinsing, drying and inspection using validated accessories.
Yes. Cleaning must precede the applicable validated sterilisation or disinfection process.
Each component must be processed according to its own IFU, which may require separate disassembly and cycles.
Check the tube, distal end, internal channel, locks, stopcock, seals and component fit.
Yes, subject to confirming compatibility with the existing telescope, obturator and working element.
A configured set may be quoted after all system requirements are confirmed.
Matching may be reviewed using catalogue details, measurements, photographs or a physical sample.
It describes an intended interface and does not imply OEM manufacture, endorsement or universal compatibility.
Dealers, distributors, importers and institutional suppliers may request bulk quotations.
Price depends on the configuration, working length, compatible components, quantity, documentation and destination.
Provide the system manufacturer, catalogue numbers, telescope dimensions, viewing angle, working-element model and clear interface photographs.
Medical and Procurement Disclaimer: This page provides general product and procurement information for qualified healthcare organisations and medical-device buyers. It is not a clinical or procedural instruction and does not replace professional training, clinical judgement, institutional protocols or product-specific instructions for use. Intended use, compatibility, reprocessing, sterilisation, supplied condition and regulatory status must be verified before purchase and use.
Contact Bharat Surgical with the required 21 Fr sheath configuration, working length, telescope model, viewing angle, obturator type, working element, blade-carrier details, quantity and delivery destination. For replacement enquiries, provide catalogue numbers and clear photographs of all connecting interfaces.
VIU Sheath 21 Fr Price Factors: Sheath-only or set supply, working length, telescope compatibility, obturator configuration, working-element interface, blade-carrier compatibility, irrigation components, included accessories, quantity, sterilisation tray, packaging, documentation, delivery destination.