ISO 13485:2016 Certified
40+ Years of Excellence
600+ Products
Download Catalog
MANUFACTURER & SUPPLIER | B2B UROLOGY INSTRUMENTS

TURP Surgery Instruments
Manufacturer & Supplier in India

Bharat Surgical manufactures and supplies reusable TURP surgery instruments for hospitals, urology centres, medical colleges, surgical-equipment dealers and international distributors. The range includes monopolar resectoscope sets, 26 Fr inner and outer sheaths, active and passive working elements, compatible telescopes, electrodes and related accessories. A TURP instrument set must be configured as one compatible system — the sheath, telescope, working element, electrode, cable and electrosurgical generator must be matched by exact technology, dimensions and connection.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
TURP Surgery Instruments surgical instrument on a clean clinical blue background
Product Range

Bharat Surgical TURP Instrument Range

For professional healthcare use only. TURP instruments must be selected, configured and used by qualified medical professionals according to the applicable instructions for use. Bharat Surgical's published range includes:

Monopolar TURP resectoscope set
TURP inner and outer sheath, 26 Fr
Working element — single-stem active
Working element — single-stem passive
Working element — double-stem active
Working element — double-stem passive
Passive 4 mm Stryker-type working element
Bi-TURP working element with extra fitting
TURP laser working element
Monopolar 2.9 mm TURP electrodes
Monopolar 4 mm TURP electrodes
Bipolar 4 mm TURP electrodes
Compatible obturators, connectors and accessories

Availability, dimensions and system compatibility should be reconfirmed in the final quotation.

Product Overview

What Are TURP Surgery Instruments?

TURP surgery instruments are components of a rigid transurethral resectoscope system. TURP refers to transurethral resection of the prostate.

A configured resectoscope system typically combines:

Rigid telescope
Inner and outer sheath
Obturator
Working element
Compatible electrode
Electrosurgical cable
Compatible generator
Irrigation connections
Camera and light-transmission equipment

Critical System Notice

A TURP instrument set must be configured as one compatible system. The sheath, telescope, working element, electrode, cable and electrosurgical generator must be matched by exact technology, dimensions and connection — not selected by appearance or nominal size alone.

Clinical selection and use are restricted to trained healthcare professionals and must follow the applicable instructions for use.

System Components

Components of a TURP Resectoscope Set

ComponentFunction within the systemDetails to confirm
Rigid telescopeProvides endoscopic visualisationDiameter, length, viewing angle and light post
Inner sheathForms part of the continuous-flow assemblySize, lock and outer-sheath compatibility
Outer sheathHouses the inner sheath and flow connectionsFrench size, length and stopcocks
ObturatorFits the selected sheath during system setupSize, profile, length and lock
Working elementControls movement of the compatible electrodeActive/passive action, stem design and telescope size
ElectrodeProvides the system-specific electrosurgical functionMonopolar/bipolar type, shape, size and connector
CableConnects the working element or electrode to the generatorInstrument-side and generator-side connections
GeneratorSupplies approved electrosurgical outputManufacturer, model, mode and accessory approval
Camera and light systemDisplays and illuminates the endoscopic fieldCoupler, telescope and light-cable compatibility
Irrigation connectionConnects the approved fluid-management arrangementStopcock, tubing and sheath configuration

The generator and fluid-management arrangement are separate systems. A generator should not be described as controlling irrigation unless the exact integrated equipment documentation establishes that function.

Specifications

TURP Inner and Outer Sheath — 26 Fr

Bharat Surgical currently publishes a 26 Fr TURP inner and outer sheath. The published specification is:

Published specificationDetails
Size26 Fr
TypeTURP inner and outer sheath
MaterialStainless steel
Material gradeSS 304
BrandBharat Surgical
Minimum order quantity5 pieces
Published applicationTURP surgery
26 Fr French Scale & Inner/Outer Configuration

French scale formula: 26 ÷ 3 = approximately 8.67 mm nominal outside diameter.

This mathematical conversion is not a substitute for the manufacturer's dimensional drawing. Working length, internal diameter, tolerances, lock and stopcock arrangement remain product-specific.

Never mix inner and outer sheaths from different systems unless compatibility has been explicitly established.
Inner sheath: fits inside the compatible outer sheath
Outer sheath: carries model-specific ports, stopcocks and obturator interface
Both must match telescope, working element and obturator as a set
Product Comparison

Monopolar vs Bipolar TURP Systems

Selection pointMonopolar systemBipolar system
Electrical circuitUses an approved monopolar circuitUses the approved bipolar electrode system
Patient return electrodeGenerally required as part of the monopolar setupDetermined by the specific bipolar system
Working elementMonopolar-compatible modelBipolar-compatible model
ElectrodeMonopolar electrodeBipolar electrode
CableMonopolar system cableBipolar system cable
GeneratorCompatible monopolar outputCompatible bipolar output
Fluid requirementMust follow complete system IFUMust follow complete system IFU
InterchangeabilityNot interchangeable — verify each component independently

Only qualified healthcare professionals should select the technology, fluid medium and generator settings. A product described as "bipolar" is not automatically compatible with every bipolar generator or resectoscope platform.

Product Details

TURP Working Elements

The working element connects the telescope, sheath and compatible electrode and controls the electrode's mechanical movement. Bharat Surgical's range includes:

Active and Passive Working Elements

FeatureActivePassive
Resting positionSystem-specific active-action arrangementSystem-specific passive-action arrangement
Electrode movementDetermined by handle and spring designDetermined by handle and spring design
Selection basisSurgeon preference and system compatibilitySurgeon preference and system compatibility
CompatibilityRequires matching electrode, telescope and sheath in both cases

"Active" and "passive" describe mechanical action — they do not indicate whether the electrosurgical technology is monopolar or bipolar.

Single-Stem and Double-Stem Working Elements

FeatureSingle-stemDouble-stem
ConstructionOne defined structural stemTwo defined structural stems
Electrode compatibilityModel-specificModel-specific
Telescope compatibilityMust be verified — not assumed
InterchangeabilityNot assumed
Product Details

TURP Electrode Types

Depending on the approved resectoscope system, electrode configurations may include:

Cutting loop electrode
Coagulation or roller electrode
Ball electrode
Knife electrode
Collin-type knife
Model-specific vaporisation electrode
Confirm Before Ordering an Electrode
Monopolar or bipolar technology
Telescope category (2.9 mm or 4 mm)
Working-element model
Electrode length, tip shape and stem
Proximal connector
Generator and cable
Reusable or single-use status
Compatibility

TURP System Compatibility Matrix

ComponentMust match
TelescopeWorking element, sheath, viewing angle and imaging system
Inner sheathOuter sheath, obturator and working element
Outer sheathInner sheath, flow arrangement and obturator
Working elementTelescope, sheath, electrode and technology
ElectrodeWorking element, telescope category, cable and generator
CableInstrument connector, generator socket and technology
GeneratorMonopolar/bipolar system and approved accessories
ObturatorExact sheath size, length, tip and lock
StopcocksSheath threads and approved tubing
Camera/light equipmentTelescope eyepiece and light post

Terms such as "Storz type" or "Stryker type" describe an intended compatibility reference and should be supported by exact catalogue numbers. Such wording does not mean the component is manufactured by the referenced OEM, that the trademark owner has approved the product, or that compatibility verification can be omitted. All third-party trademarks remain the property of their respective owners.

Selection Guide

Selecting the Correct TURP Instruments

Before requesting a quotation, determine:

Monopolar or bipolar system
Complete set or replacement component
Sheath size and working length
Telescope diameter and viewing angle
Active or passive working element
Single- or double-stem design
Electrode type and shape
Generator manufacturer and model
Cable connectors
Obturator configuration
Irrigation and stopcock requirements
Reprocessing requirements
Required quantity and spares
Documentation and destination market
Cleaning & Care

Pre-Use Inspection Checklist

Authorised personnel should verify before every use:

Sheaths are straight and correctly matched
Channels are unobstructed
Obturator fits the selected sheath
Telescope is undamaged and correctly aligned
Working element moves according to specification
Electrode is correctly seated and aligned
Electrode insulation is intact
Cable and connectors show no visible damage
Stopcocks move and close correctly
Seals are present and undamaged
Monopolar/bipolar components have not been mixed
Generator compatibility is documented
Reprocessing status is complete — damaged or incompatible components must be removed from service.
Cleaning & Care

Cleaning and Reprocessing

Reprocessing Care Guidelines

Reusable TURP instruments contain narrow channels, locks, springs, hinges, insulation and electrical connectors that require validated cleaning and reprocessing. The FDA describes reusable-device reprocessing as a multistep process involving cleaning followed by appropriate disinfection or sterilisation.

Always follow each component's current IFU. Steam sterilisation should be used only when the IFU validates it for the exact component. The sheath, telescope, working element, electrode and cable may have different processing instructions.

General Reprocessing Checklist
Follow each component's current IFU.
Begin point-of-use treatment as directed.
Separate telescope, sheaths, obturator, working element and cable.
Remove electrodes; open stopcocks and detachable parts.
Brush and flush accessible lumens.
Operate working-element mechanisms during cleaning when directed.
Rinse and dry all channels and components.
Inspect electrical insulation and connectors.
Use only validated sterilisation or disinfection cycles.
Maintain reprocessing and traceability records.
Procurement

Example TURP Set BOQ

Monopolar TURP Set BOQ

ComponentSuggested qty
Compatible rigid telescope1
Inner and outer sheath1 set
Matching obturator1
Monopolar working element1
Compatible monopolar electrodesAs required
Compatible monopolar cable1
Approved patient return accessoriesAs per generator IFU
Irrigation connectors1 set
Light cable1
Camera coupler1
Cleaning accessories1 set
Sterilisation tray1

Bipolar TURP Set BOQ

ComponentSuggested qty
Compatible rigid telescope1
Inner and outer sheath1 set
Matching obturator1
Bipolar working element1
Compatible bipolar electrodesAs required
Compatible bipolar cable1
Irrigation connectors1 set
Light cable1
Camera coupler1
Cleaning accessories1 set
Sterilisation tray1

These are procurement templates, not procedural setup guides. Final configurations must be approved by qualified clinical, biomedical and sterile-services personnel.

Selection Guide

Why Source TURP Instruments from Bharat Surgical?

Monopolar TURP resectoscope-set enquiries
Published 26 Fr SS 304 inner and outer sheath
Active and passive working elements
Single- and double-stem configurations
2.9 mm and 4 mm instrument categories
Monopolar and bipolar electrode options
Hospital, dealer and export supply support
Compatibility-based technical quotations
ISO 13485:2016 certified manufacturer
40+ years of surgical instrument manufacturing experience

All dimensions, material grades, compatibility, supplied components, reusable status and regulatory documentation must be verified in the final quotation.

Immediate Answers

Frequently Asked Questions

Technical, compatibility, ordering and reprocessing answers for the Bharat Surgical TURP Surgery Instruments range.

They are components of a rigid transurethral resectoscope system, including a telescope, sheath, working element, electrode and related accessories.

TURP means transurethral resection of the prostate.

Bharat Surgical publishes TURP sheaths, working elements, electrodes and a monopolar resectoscope-set category.

A configured set may be quoted after the technology and compatibility requirements are confirmed.

Bharat Surgical publishes a 26 Fr inner and outer sheath.

The published specification identifies 304-grade stainless steel.

The mathematical French-scale conversion is approximately 8.67 mm.

The published page states a minimum order quantity of five pieces. Current commercial terms should be reconfirmed.

It is the mechanism that connects with the telescope, sheath and compatible electrode and controls electrode movement.

It is a model with an active-action mechanical arrangement. Exact movement depends on the system design.

It is a model with a passive-action mechanical arrangement. Exact movement depends on the system design.

No. Active or passive describes mechanical action, not electrosurgical technology.

It is a working element constructed with one defined structural stem.

It is a working element constructed with two defined structural stems.

No universal interchangeability should be assumed.

They use different electrical systems, electrodes, cables, working elements and generator connections.

It should not be used unless that exact cross-compatibility is documented by the applicable system manufacturer.

A monopolar system generally uses an approved patient return arrangement. Follow the generator and accessory IFUs.

Fluid selection is a clinical and system decision governed by the complete device, generator and institutional instructions.

Published and model-dependent options may include loops, knives and ball or roller configurations. Confirm exact availability.

Bharat Surgical publishes a monopolar 2.9 mm TURP electrode category.

Bharat Surgical publishes monopolar and bipolar 4 mm TURP electrode categories.

No. It generally refers to the telescope category, not the complete assembled sheath diameter.

No. Length, viewing angle, lock and working-element interface must also match.

Only if specifically listed in the quotation. A generator is normally specified separately.

No. Both connectors, technology and electrical rating must be compatible.

Selected components may be reusable. Confirm each product's classification and IFU.

Not necessarily. Reusable design and supplied sterile condition are separate specifications.

Only when each component's IFU validates steam sterilisation.

Follow the IFU for disassembly, brushing, flushing, rinsing, drying and inspection.

Check mechanical movement, locks, springs, electrode seating, insulation and visible cleanliness.

Yes, subject to confirming compatibility with the telescope, sheath, electrode and generator system.

Yes, but the exact working element, telescope category, technology and generator must be identified.

Matching may be reviewed using catalogue numbers, dimensions, photographs or a physical sample.

It describes an intended compatibility reference and does not imply OEM manufacture, endorsement or universal fit.

Price depends on technology, components, dimensions, electrode quantity, compatibility, documentation and destination.

Provide the sheath, telescope, working element, electrode, cable and generator specifications.

Dealer, institutional and export enquiries may be submitted subject to availability and destination requirements.

Medical and Procurement Disclaimer: This page provides general product and procurement information for qualified healthcare organisations and medical-device buyers. It is not a clinical, electrosurgical or procedural instruction and does not replace professional training, clinical judgement, institutional protocols or product-specific instructions for use. Compatibility, fluid selection, generator settings, reprocessing, sterile supply and regulatory status must be verified before purchase and use.

Request TURP Surgery Instrument Price

TURP instrument pricing varies according to monopolar or bipolar technology, components, sheath size, working element, electrode type, quantity and delivery destination. Contact Bharat Surgical with the required system details, sheath size, telescope model, working-element type, electrode reference, generator model, quantity and delivery destination. For replacement components, include catalogue numbers and clear photographs of all interfaces.
Factors Affecting Price: Monopolar or bipolar technology, complete set or individual component, telescope category, sheath size, working-element design, electrode type and quantity, cable and generator compatibility, accessories, order quantity, sterilisation tray, documentation, delivery destination