Bharat Surgical manufactures and supplies reusable laparoscopic aspiration needles with stainless-steel construction and a tubing connector for hospital, gynecology and laparoscopic instrument requirements. A published model is listed with a 16 G needle, 5 mm shaft diameter and 120 mm working length. Hospitals, surgical centres, medical colleges, dealers and distributors can request exact needle-tip specifications, shaft dimensions, tubing compatibility, reprocessing documentation and current prices.
A laparoscopic aspiration needle is a long-shaft instrument designed to provide a controlled fluid pathway during selected minimally invasive procedures. It commonly incorporates a needle tip, tubular shaft, handle or connector assembly and a connection for compatible aspiration tubing.
The correct product must be selected according to its intended application, needle gauge, shaft diameter, working length, tip configuration, tubing connection and reusable or single-use status.
Bharat Surgical’s current listings identify reusable stainless-steel laparoscopic aspiration needle configurations for gynecological and general laparoscopic requirements.
| Published configuration | Specification | |
|---|---|---|
| Needle gauge | 16 G | |
| Shaft diameter | 5 mm on the laparoscopic-instrument listing | |
| Working length | 120 mm | |
| Channel connection | Tubing connector | |
| Material | Stainless steel | |
| Finish | Polished | |
| Usage type | Reusable | |
| Sterilization description | Autoclavable | |
| Application | Laparoscopic and hospital use | |
| Brand | Bharat Surgical | |
| Country of origin | India |
These specifications are drawn from Bharat Surgical’s laparoscopic aspiration needle listing. A separate gynecology listing shows a 10 mm diameter, while the laparoscopic range shows 5 mm. Buyers must therefore confirm the correct diameter using the current product code or technical drawing.
| Specification | Published information |
|---|---|
| Product name | Laparoscopic Aspiration Needle |
| Needle gauge | 16 G |
| Working length | 120 mm |
| Published shaft diameter | 5 mm |
| Connection | Tubing connector |
| Material | Stainless steel |
| Finish | Polished |
| Reusability | Reusable |
| Sterilization | Autoclavable |
| Sterile status | Inconsistently listed |
| Application | Laparoscopic aspiration |
| Brand | Bharat Surgical |
| Origin | Made in India |
Some current marketplace fields appear inconsistent:
Procurement Advisory
These fields should not be copied directly into a hospital BOQ. Request a current technical sheet confirming the instrument’s classification, diameter, gauge, working length, sterile supply status and material grade.
A reusable laparoscopic aspiration needle may include:
Procurement Notice: The exact assembly and whether components are detachable must be confirmed for the selected model.
Before requesting a quotation, specify:
Procurement Notice: Clinical suitability and procedural selection must be determined by qualified medical personnel.
| Selection factor | 5 mm configuration | 10 mm configuration |
|---|---|---|
| Published status | Listed in the laparoscopic instrument range | Listed on a separate gynecology page |
| Working length | 120 mm published | 120 mm shown on the separate listing |
| Needle gauge | 16 G published | 16 G shown on the separate listing |
| Access requirement | Compatible 5 mm or larger port, subject to actual diameter | Compatible 10 mm or larger port, subject to actual diameter |
| Tubing connector | Listed | Listed |
| Current availability | Confirm | Confirm |
| Final selection | Based on product code and verified dimensions | Based on product code and verified dimensions |
Because the online specifications conflict, the website should not present both diameters as confirmed standard variants unless Bharat Surgical verifies them.
An aspiration needle and a Veress needle should not be treated as the same product merely because one marketplace field uses the term “Veress.”
| Feature | Aspiration Needle | Veress Needle |
|---|---|---|
| Main product function | Provides a pathway for aspiration through compatible tubing | Used as an access needle for creating pneumoperitoneum according to approved technique |
| Connection | Aspiration or tubing connector | Insufflation connector |
| Fluid or gas pathway | Intended for aspiration | Intended for insufflation |
| Distal construction | Model-specific aspiration tip | Typically incorporates a spring-loaded blunt stylet |
| Selection basis | Gauge, lumen, shaft, tubing and application | Length, diameter, valve, stylet and insufflator compatibility |
| Interchangeability | Should not be assumed | Should not be assumed |
Bharat Surgical’s aspiration and Veress needles should have separate product codes, technical sheets and website pages.
| Feature | Aspiration Needle | Suction–Irrigation Instrument |
|---|---|---|
| Distal profile | Needle tip | Cannula or probe |
| Published connection | Tubing connector | Suction and/or irrigation connection |
| Main pathway | Aspiration lumen | Larger suction or irrigation channel |
| Typical shaft profile | Narrow needle and shaft assembly | Cannula-style instrument |
| Flow control | Model-specific | Trumpet, thumb-control or other valve may be provided |
| Procurement category | Needle instrument | Suction–irrigation instrument |
| Interchangeability | Not a general substitute | Not a general substitute |
The instrument should be chosen according to the required function and surgeon-approved clinical protocol.
These three measurements describe different parts of the instrument:
Relates to the needle or internal cannula specification.
Relates to the outer laparoscopic portion that must pass through the trocar.
Affects the internal fluid pathway and connector matching.
A published 16 G needle with a 5 mm shaft does not mean the complete fluid channel is 5 mm. Hospitals should request a dimensioned technical drawing when exact lumen and flow requirements matter.
Before approving the product, verify:
Do not rely only on a “5 mm” or “10 mm” product description.
The published model includes a tubing connector, but its precise interface is not specified. Buyers should confirm:
Do not assume that any available suction tubing will fit the instrument securely.
| Selection factor | Reusable needle | Single-use needle |
|---|---|---|
| Published Bharat Surgical model | Reusable | Not confirmed on current listing |
| Reprocessing | Required after each use | Normally not reprocessed |
| Inspection | Required before and after reprocessing | Packaging and integrity checked before use |
| Documentation | IFU and validated cleaning process required | Sterility and disposal documentation required |
| Procurement cost | Instrument plus reprocessing cost | Per-procedure purchase and disposal cost |
| Selection basis | Hospital policy, intended use and validated workflow | Hospital policy and model availability |
Bharat Surgical’s published aspiration needle is reusable, but its exact reuse limitations must be confirmed from the current IFU.
Inspect the complete instrument for:
Any instrument with a damaged tip, blocked lumen, loose connector, visible corrosion or leakage should be removed from service and assessed according to hospital policy.
A reusable aspiration needle contains a narrow internal lumen that must be cleaned and inspected according to validated instructions.
General considerations include:
The term “autoclavable” alone is not a complete reprocessing instruction. Hospitals require validated temperature, pressure, exposure, drying and packaging parameters.
Bharat Surgical can support enquiries for:
Before technical approval, hospitals should request the current product code, dimensions, IFU, connector details and sterile-supply declaration.
Dealers, importers and distributors may enquire about:
Commercial terms and product availability should be confirmed in writing.
"Reusable laparoscopic aspiration needle, 16 G needle specification, [5 mm/confirmed diameter] shaft, 120 mm working length, stainless-steel construction, polished finish, compatible tubing connector, suitable for validated hospital reprocessing, supplied with product-specific IFU and technical documentation."
The final BOQ must use the verified diameter, connector type, lumen specification, sterile status and material grade for the selected product code.
All technical details should be confirmed against the selected product code before purchase.
Find technical, reprocessing, ordering, and size compatibility answers for the Bharat Surgical Aspiration Needle range.
It is a long-shaft needle instrument with an internal fluid pathway and connector intended for selected laparoscopic aspiration requirements.
The current detailed listing states a 16 G needle specification.
The main laparoscopic listing states 5 mm. A separate listing states 10 mm, so the correct diameter must be confirmed by product code.
A working length of 120 mm is published for the detailed model.
The instrument is listed with stainless-steel construction and a polished finish.
Yes. Bharat Surgical’s detailed listing describes it as reusable.
It is described as autoclavable, but hospitals must obtain the complete validated reprocessing cycle from the current IFU.
The published information is inconsistent. Confirm whether the selected model is supplied sterile or non-sterile.
Yes. A tubing connector is listed, but its exact dimensions and interface must be confirmed.
Tubing inclusion is not clearly specified. Request written confirmation in the quotation.
Not necessarily. Verify the connector type and the tubing’s internal diameter before purchase.
Not automatically. Compare the maximum instrument diameter with the trocar’s internal diameter and valve construction.
A reducer may be suitable when all dimensions and valve interfaces are compatible. Verify the complete combination before approval.
No. They are intended for different functions. A marketplace field uses the term “Veress,” but Bharat Surgical should confirm the selected product’s correct classification.
No. An aspiration needle has a needle-style distal end and generally a narrower lumen, while a suction–irrigation instrument uses a cannula or probe with model-specific flow controls.
It is the published needle-gauge specification. It should not be confused with the instrument’s outer shaft diameter.
No. The published model separately lists a 16 G needle and a 5 mm shaft diameter.
The internal lumen diameter is not clearly published. Request a dimensioned drawing if lumen size is important.
Follow the model-specific IFU and hospital’s validated CSSD procedure using compatible flushing and channel-cleaning equipment.
Inspect the openings and perform only the patency or flow test approved by the product IFU and hospital protocol.
It should be removed from service and assessed by qualified personnel. Do not attempt to straighten it in the operating department.
Inspect the tip, shaft, lumen, handle, connector, joints, surface condition and product markings.
Only if the current product-specific IFU permits it.
Use a tip-protection method that is compatible with the IFU and sterilization process and does not interfere with sterilant contact.
A technical sample may be requested, subject to availability and Bharat Surgical’s commercial policy.
Yes. Medical colleges can enquire about individual instruments or complete laparoscopic training sets.
Hospitals, dealers and distributors can request quantity-based quotations.
Provide the required gauge, diameter, length, tip type, connector, trocar size, tubing details, quantity and delivery location.
Request the technical sheet, product code, IFU, material confirmation, sterile-status declaration, connector details and current quotation.
OEM or private-label availability must be confirmed based on the required specification, quantity and destination market.
Aspiration Needle pricing varies according to technical specifications, quantity, packaging, and delivery destination. Send your configuration details to receive a current B2B quotation.
Factors Affecting Price: Needle gauge, Shaft diameter, Working length, Tip design, Internal lumen, Tubing connector, Stainless-steel grade, Reusable construction, Sterile or non-sterile supply, Tubing or adapter inclusion, Required documentation, Order quantity, Packaging, Domestic or export delivery, Taxes and freight