Bharat Surgical manufactures and supplies reusable laparoscopic trocar reducers for hospitals, surgeons, surgical centres, dealers and medical-equipment distributors. The published range includes a flip-top trocar reducer designed to adapt a larger trocar cannula for the passage of a smaller-diameter laparoscopic instrument. Bharat Surgical currently lists a 10 mm to 5 mm reducer made using metal, plastic and silicone components.
A trocar reducer is an accessory fitted to a trocar cannula to reduce its working opening. It enables a smaller-diameter laparoscopic instrument to pass through a larger trocar port without replacing the complete cannula.
For example, a compatible 10 mm to 5 mm reducer allows a specified 5 mm instrument to be introduced through a 10 mm trocar cannula.
Bharat Surgical’s published model is a reusable flip-top reducer incorporating metal, plastic and silicone components.
Its basic construction includes:
The hinged upper section allows the reduced opening to be moved into or out of position according to the product design.
The main body provides the mounting structure through which the smaller instrument is passed.
The silicone component is intended to fit around the smaller instrument and support the sealing function of the reducer.
Usage Guide: The condition, alignment and compatibility of all three components should be checked before the reducer is placed into service.
| Specification | Published details |
|---|---|
| Product name | Flip-Top Metal, Plastic and Silicone Reducer |
| Product type | Laparoscopic trocar reducer |
| Conversion size | 10 mm to 5 mm |
| Construction | Flip-top design |
| Materials | Metal, plastic and silicone |
| Usage type | Reusable |
| Application | Laparoscopic surgery |
| Mounting | Trocar-cannula accessory |
| Brand | Bharat Surgical |
| Country of supply | India |
Bharat Surgical’s existing product listing identifies the reducer as a reusable 10 mm to 5 mm flip-top configuration manufactured from metal, plastic and silicone components. Bharat Surgical trocar reducer listing.
Final dimensions, compatible cannula models, supplied components and reprocessing instructions should be confirmed before ordering.
A 10 mm to 5 mm reducer is designed to connect with a specified 10 mm trocar cannula and provide an opening for a compatible 5 mm laparoscopic instrument.
The first measurement normally refers to the trocar or cannula size. The second refers to the smaller instrument size accommodated by the reducer.
However, nominal diameter alone does not confirm compatibility. Buyers must also verify:
A reducer may be required when the surgical team wants to introduce a smaller instrument through an existing larger trocar port.
Typical procurement situations include:
The responsible surgeon or department should determine whether a reducer is appropriate for the intended instrument system and procedure.
Identify the nominal diameter of the trocar cannula to which the reducer will be connected.
Specify the diameter of the instrument that must pass through the reduced opening.
Clearly state the required conversion, such as 10 mm to 5 mm.
Mention whether the existing system uses a flip-top, top-mounted, push-fit or another reducer design.
Provide the brand, model, product code or clear photographs of the trocar head and cannula.
Ask whether the reducer contains an integrated seal and whether replacement silicone components are available.
Obtain the cleaning, disassembly and sterilization instructions applicable to the supplied reducer.
Two reducers may have the same nominal conversion size but differ in:
An incompatible reducer may not attach correctly or may not provide the intended sealing function. Buyers should therefore submit photographs and measurements when ordering a replacement.
| Product | Primary function | |
|---|---|---|
| Trocar cannula | Provides the main access passage for laparoscopic instruments | |
| Trocar reducer | Adapts a larger cannula opening for a smaller instrument | |
| Obturator or trocar pin | Forms part of the access-entry assembly | |
| Seal or valve | Supports sealing around the inserted instrument |
A trocar reducer is an accessory. It does not replace the cannula, obturator or complete trocar assembly.
Buyers requiring trocar reducers may also need:
Hospitals can procure trocar reducers as individual replacement accessories or as part of a broader laparoscopic-instrument requirement.
The enquiry should specify whether the reducer is required for:
A product photograph or sample reference can help identify the required mounting and conversion.
Bharat Surgical accepts trocar-reducer enquiries from surgical-instrument dealers, distributors and medical-equipment suppliers.
For commercial review, provide:
Private labelling, dealership terms and customised packing should only be confirmed through a written quotation or agreement.
Reusable trocar reducers may contain joints, seals and different material components. The healthcare facility should obtain and follow the instructions supplied with the specific product.
Inspection should include:
Sterilization Notice: Do not publish or apply a universal sterilization temperature or cycle without verified model-specific instructions.
Provide the following information for an accurate quotation:
Exact compatibility, component inclusion, documentation, price and delivery terms must be confirmed through the applicable quotation.
Find technical, reprocessing, ordering, and size compatibility answers for the Bharat Surgical Trocar Reducer range.
A laparoscopic trocar reducer is an accessory that adapts a larger trocar cannula opening for the passage of a smaller-diameter instrument.
It is a reducer intended to connect with a compatible 10 mm trocar cannula and accommodate a specified 5 mm laparoscopic instrument.
Bharat Surgical lists a reusable flip-top trocar reducer among its laparoscopic instrument products.
The published Bharat Surgical configuration is 10 mm to 5 mm.
The listed reducer contains metal, plastic and silicone components.
Yes. The current product listing identifies it as a reusable reducer.
A flip-top reducer uses a hinged upper section that allows the reduced opening to be moved according to the product’s design.
The silicone component is intended to fit around the smaller instrument and support the reducer’s sealing function.
No. Nominal diameter alone does not establish compatibility. Mounting style, head design, seal arrangement and dimensions must also match.
Yes, subject to availability and compatibility confirmation. Provide details of the existing trocar system.
Send clear photographs of the trocar head, cannula opening, mounting area, existing reducer and any visible product markings.
No. A reducer is fitted to a compatible cannula to decrease the working opening. It does not replace the cannula.
Only when the reducer is confirmed as compatible with the particular safety-trocar system. Do not assume universal compatibility.
Compatibility depends on the Hasson trocar’s cannula-head design and dimensions. Submit the exact system details for assessment.
Availability depends on the reducer model. Mention whether you need a complete reducer or only a replacement seal.
Follow the instructions supplied for the specific model and the hospital’s validated reusable-instrument processing procedure.
Check the hinge, plastic body, silicone seal, mounting fit, cleanliness and compatibility with the intended instrument and cannula.
Yes. Hospitals can submit size-wise quantities or include reducers in a consolidated laparoscopic-instrument BOQ.
Yes. Dealers and distributors can submit the required conversion, quantity, destination and packing requirements for commercial review.
Send the required conversion size, design, quantity, existing trocar details and delivery destination to receive a current quotation.
Trocar-reducer prices can vary according to conversion size, design, materials, compatibility, quantity, packing and delivery destination. Send the required specifications or upload photographs of the existing trocar and reducer to receive the appropriate quotation.