ISO 13485:2016 Certified
40+ Years of Excellence
600+ Products
Download Catalog
MANUFACTURER & SUPPLIER | B2B LAPAROSCOPIC INSTRUMENTS

Vaginal Tube and Vaginal Blocker
Manufacturer, Supplier and Exporter in India

Bharat Surgical manufactures and supplies reusable vaginal tubes and vaginal blockers for hospitals, gynecology centres, medical colleges, surgical-instrument dealers and international distributors. These instruments are selected for compatible laparoscopic gynecology and uterine-manipulation systems. Vaginal tubes and vaginal blockers are available in different designs and dimensions. The required diameter, length, distal profile, sealing arrangement, material and compatibility with the uterine manipulator must be confirmed before ordering.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Vaginal Tube & Vaginal Blocker surgical instrument on a clean clinical blue background
Product Overview

What Is a Vaginal Tube?

A vaginal tube is a rigid or semi-rigid gynecology instrument designed for use during an authorised laparoscopic procedure. Depending on its design, it may provide a defined tubular profile, support identification of the vaginal boundary and form part of a system intended to limit gas leakage after the vaginal opening has been created.

Published medical literature describes the use of a vaginal tube as an instrument aid during laparoscopic hysterectomy. See the indexed PubMed reference on vaginal-tube use.

Clinical Notice & Safety Guidance

The exact intended use depends on the tube’s design and manufacturer’s instructions. This page does not provide procedural guidance.

Product Overview

What Is a Vaginal Blocker?

A vaginal blocker is a gynecological instrument or accessory designed to form part of a vaginal sealing arrangement during laparoscopic procedures. Depending on the system design, it may function as:

Standalone Reusable Component
Uterine Manipulator Shaft Accessory
Integrated Fornix Delineator Cup
Vaginal Tube Sealing Plug
Inflatable Silicone Balloon Seal
System-Specific Sized Blocker

Clinical Notice & Safety Guidance

In laparoscopic pelvic surgeries (such as Total Laparoscopic Hysterectomy), vaginal blockers are critical for maintaining pneumoperitoneum. They prevent abdominal gas loss following colpotomy and protect surrounding vaginal tissues from thermal or mechanical trauma.

Vaginal Tube & Vaginal Blocker Details

Bharat Surgical Product Status

Vaginal Tube & Vaginal Blocker appears as a Level 3 page in the supplied Bharat Surgical sitemap. However, Bharat Surgical’s currently indexed public website does not provide a dedicated product page or verified specifications for these products.

The following details must therefore be confirmed before the page is published with final product data:

Available tube diameters
Tube length
Straight or angled profile
Open or closed proximal end
Cap or sealing mechanism
Blocker diameter
Inflatable or solid construction
Material
Reusable or single-use status
Sterile or non-sterile supply
Compatible uterine manipulator
Validated cleaning and sterilisation method
Minimum order quantity

Unverified marketplace dimensions should not be presented as Bharat Surgical specifications.

BSC Product Range

Vaginal Tube and Blocker Range

Available or custom-quoted configurations may include:

Reusable vaginal tube
Straight vaginal tube
Angled or bevelled vaginal tube
Open-ended vaginal tube
Vaginal tube with removable cap
Vaginal tube with sealing opening
Solid vaginal blocker
Inflatable vaginal blocker
Uterine-manipulator vaginal blocker
Fornix delineator with blocker
Replacement vaginal blocker
Vaginal tube and blocker set
Custom size, subject to feasibility and validation

Availability depends on the required design, dimensions, quantity and documentation.

Product Comparison

Vaginal Tube vs Vaginal Blocker

Selection point Vaginal tube Vaginal blocker
Basic design Tubular instrument Plug, disc, balloon or system-specific sealing component
Primary system role Provides a defined tubular vaginal interface Forms part of the compatible sealing arrangement
Length Usually a significant procurement dimension Model-dependent
Diameter Tube outside and inside diameters must be specified Blocker outside diameter must be specified
Connection May include a cap or open end May connect to a manipulator shaft or separate system
Compatibility Size, profile and cap arrangement Manipulator, tube, shaft and sealing system
Interchangeability Not universally interchangeable Not universally interchangeable

The two products should be listed separately in the quotation even when supplied as a set.

System Components

Vaginal Tube Components

Depending on its design, a vaginal tube may include:

Component Function within the product Details to confirm
Tube body Provides the main tubular structure Outside diameter, inside diameter and length
Distal rim Forms the internal end profile Rounded, bevelled or model-specific
Proximal end External end of the tube Open, capped or connector-based
Removable cap Closes the tube where applicable Attachment, opening and seal
Sealing opening Provides model-specific manual or accessory closure Diameter and design
Orientation mark Identifies the profile or bevel direction Marking type and visibility
Handle or grip Assists model-specific handling Fixed or detachable
Insert or plug Fits the selected tube Diameter, length and material

Not every vaginal tube includes all these components.

System Components

Vaginal Blocker Components

Depending on the system, a vaginal blocker may incorporate:

Solid blocker body

Central opening

Manipulator-shaft connection

Inflatable balloon

Inflation channel

Inflation connector

Sealing disc

Locking collar

Retaining mechanism

Replaceable seal

Size or orientation marking

Procurement Notice: The presence of a balloon, inflation channel or valve should never be assumed unless stated in the product specification.

Vaginal Tube & Vaginal Blocker Details

Vaginal Tube Sizes

Vaginal tubes are sold in different market sizes, but Bharat Surgical’s exact size range has not yet been publicly verified.

For a quotation, buyers should specify:

Tube outside diameter
Tube inside diameter
Overall length
Usable length
Distal-rim shape
Straight or angled profile
Cap requirement
Blocker compatibility
Quantity

The required dimensions are selected by qualified clinical personnel. The website should not recommend a size based on patient characteristics.

Vaginal Tube & Vaginal Blocker Details

Vaginal Blocker Sizes

A vaginal blocker should be specified by:

Maximum outside diameter
Central-opening diameter
Thickness or axial length
Compatible shaft diameter
Solid or inflatable construction
Inflation limit stated in the IFU, if applicable
Compatible uterine manipulator
Required material
Reusable or single-use status

Do not describe a blocker as “one size fits all” unless that claim is supported by the product documentation.

Vaginal Tube & Vaginal Blocker Details

Vaginal Tube Profiles

Profile General construction Procurement check
Straight tube Uniform or near-uniform tube body Diameter, length and rim
Bevelled tube Distal rim has a defined angled profile Bevel direction and orientation marking
Open-ended tube Includes an open central lumen Internal diameter and cap option
Capped tube Includes a removable or fixed proximal cap Seal, opening and attachment
System-specific tube Designed around another instrument platform Catalogue number and compatibility

Clinical selection is outside the scope of this product page.

Vaginal Tube & Vaginal Blocker Details

Vaginal Blocker Configurations

Configuration General construction Details to verify
Solid blocker Non-inflatable body Diameter, central opening and material
Inflatable blocker Includes a model-specific balloon Inflation medium, connector and limit stated in IFU
Shaft-mounted blocker Fits a compatible manipulator shaft Shaft diameter and locking mechanism
Integrated blocker Part of a manipulator or fornix system Complete system model
Standalone blocker Used as a separate component Shape, size and authorised application
Vaginal Tube & Vaginal Blocker Details

Compatibility with Uterine Manipulators

A vaginal blocker may form part of a uterine-manipulator system. Confirm:

Manipulator manufacturer
Exact model
Shaft diameter
Shaft length
Cup or fornix-delineator design
Blocker central opening
Blocker position
Locking or retaining mechanism
Reusable or single-use classification
Reprocessing method

A blocker from one manipulator should not be used on another system solely because the central hole appears to fit.

Vaginal Tube & Vaginal Blocker Details

Compatibility with Vaginal Tubes

Where the tube and blocker are used as one system, verify:

Tube outside diameter
Tube inside diameter
Blocker outside diameter
Insert depth
Sealing surface
Cap or plug interface
Orientation
Material compatibility
Reprocessing compatibility
Supplied-component list

Physical fit does not by itself establish that the combination is intended or validated.

Product Comparison

Vaginal Tube vs Uterine Manipulator

Feature Vaginal tube Uterine manipulator
Main structure Tubular vaginal instrument Shaft-and-handle manipulation system
Uterine-cavity component Not automatically included May include a model-specific intrauterine tip
Directional manipulation Not its assumed primary function Model-dependent manipulation function
Blocker May be separate or integrated May include a compatible blocker
Cup or delineator Model-dependent May be part of the manipulator set
Interchangeability Not interchangeable Not interchangeable

A vaginal tube should not be marketed as a uterine manipulator unless its documented design provides that function.

Product Comparison

Vaginal Blocker vs Vaginal Occluder

The terms “vaginal blocker,” “vaginal occluder” and “pneumoperitoneum occluder” may be used differently across product catalogues.

Before ordering, identify:

Whether the product is solid or inflatable
Whether it is standalone or shaft-mounted
Its intended instrument system
Diameter and length
Connection and valve
Reusable or single-use status
Supplied sterile condition

A product name alone is insufficient for compatibility confirmation.

Vaginal Tube & Vaginal Blocker Details

Material Options

Vaginal tubes and blockers may be manufactured from polymer, silicone, metal, ceramic or a combination of materials, depending on the model. Bharat Surgical’s actual materials must be verified before publication.

The technical quotation should state:

Material of the tube body
Material of the distal rim
Material of the cap
Blocker material
Balloon material, if applicable
Metal grade, if applicable
Latex status
Reusable or single-use classification
Cleaning-agent compatibility
Sterilisation compatibility

Do not claim “latex-free,” “BPA-free,” “medical-grade silicone” or a specific stainless-steel grade without supporting documentation.

Product Comparison

Reusable vs Single-Use Products

Procurement point Reusable product Single-use product
Use cycle Multiple uses under validated reprocessing instructions One use as labelled
Cleaning Required after use Not intended for routine reuse
Sterilisation Follow validated IFU Supplied condition must be confirmed
Inspection Required before each release Packaging and expiry checked before use
Documentation IFU, reprocessing and service criteria Sterility, shelf life and disposal
Cost evaluation Purchase plus reprocessing and replacement Per-unit purchase and disposal

The supplied classification must be confirmed for both the vaginal tube and blocker.

Vaginal Tube & Vaginal Blocker Details

Sterile Supply Status

Reusable does not mean sterile, and single-use does not automatically mean sterile.

Before purchase, confirm:

Supplied sterile or non-sterile
Sterilisation method
Sterile-barrier packaging
Manufacturing and expiry dates
Shelf life
Storage requirements
Instructions before first use
Packaging quantity
Cleaning & Care

Reprocessing Reusable Vaginal Tubes

Reprocessing Care Guidelines

Reusable vaginal tubes may have lumens, caps, openings, grooves and detachable parts requiring validated cleaning.

The US FDA describes reusable-device reprocessing as a multistep process involving cleaning followed by appropriate disinfection or sterilisation. Read the FDA’s reusable-device reprocessing information.

Reprocessing Checklist
Cleaning & Care

General Reprocessing Considerations

Reprocessing Care Guidelines

Cleaning must precede sterilisation or high-level disinfection. See the CDC disinfection and sterilisation guideline.

Reprocessing Checklist
Follow the current product-specific IFU.
Begin point-of-use treatment as directed.
Remove caps, blockers, seals and detachable parts where instructed.
Brush the internal and external tube surfaces.
Flush all accessible openings and channels.
Clean around the rim, cap threads and sealing surfaces.
Use only compatible cleaning agents.
Rinse and dry all surfaces thoroughly.
Inspect for cracks, deformation, staining and retained soil.
Use only a validated sterilisation or disinfection cycle.
Protect the processed instrument during storage.
Maintain facility reprocessing records.
Cleaning & Care

Reprocessing Reusable Vaginal Blockers

Reprocessing Care Guidelines

For a reusable blocker, authorised personnel should follow the IFU for:

Inflatable components require particular attention to valves and channels. Do not immerse or process them using a method not permitted by the manufacturer.

Reprocessing Checklist
Disassembly
Cleaning the central opening
Cleaning the shaft connection
Cleaning sealing surfaces
Flushing any inflation channel
Testing the balloon where specified
Drying all internal spaces
Inspecting for cracks, cuts or deformation
Validated sterilisation
Storage and service-life controls
Vaginal Tube & Vaginal Blocker Details

Can Vaginal Tubes and Blockers Be Autoclaved?

Only use steam sterilisation when the product-specific IFU validates it for the exact material and construction.

A polymer tube, silicone blocker, balloon valve and metal component may have different processing limitations.

Confirm:

Validated sterilisation method
Required disassembly
Cycle parameters
Material compatibility
Drying requirements
Packaging and tray requirements
Maximum reuse or inspection criteria
Selection Guide

Pre-Use Inspection Checklist

Before release for use, authorised personnel should check:

Correct tube and blocker sizes have been selected
Tube body is free from cracks or deformation
Distal rim is smooth and undamaged
Internal lumen is unobstructed
Cap fits correctly, where supplied
Blocker retains its specified shape
Central opening is undamaged
Shaft connection is secure
Balloon and valve pass the manufacturer’s specified check, if applicable
No visible soil, staining or deterioration is present
Product identification is legible
Reprocessing status is complete
Damaged, incomplete or incompatible components should be removed from service.
Procurement Template

Example Vaginal Tube and Blocker BOQ

This template represents a typical Bill of Quantities (BOQ) structure for purchasing a complete reusable Vaginal Tube and Blocker setup:

Item Code Description / Technical Specification Material / Type Qty Unit
BS-VT-35S Vaginal Tube (Straight Distal Rim): 35 mm Outer Diameter, 32 mm Inner Diameter, 150 mm Working Length. Smooth polished edges. Medical-grade Stainless Steel 2 Units
BS-VT-35B Vaginal Tube (Bevelled Distal Rim): 35 mm Outer Diameter, 32 mm Inner Diameter, 150 mm Working Length with angled bevelled distal end. Medical-grade Stainless Steel 2 Units
BS-VB-35P Vaginal Blocker Plug: Solid reusable occlusive plug compatible with 35 mm vaginal tubes to secure gas sealing. High-density Delrin / Silicone 4 Units
BS-VB-INF Inflatable Vaginal Blocker: Autoclavable silicone expansion blocker compatible with uterine manipulator shafts. Medical-grade Silicone 2 Units
BS-VB-SEAL Replacement Gaskets: Autoclave-compatible sealing O-rings and gas-barrier gaskets for tubes and blockers. Fluoropolymer / Silicone 20 Pieces
BS-ACC-BRUSH Cleaning Brush Set: Modular heavy-duty brushes specifically sized for internal lumen scrubbing of vaginal tubes. Nylon bristles / SS Core 2 Sets

Note on Procurement: Quantities and sizing are illustrative. Prior to final B2B tender submission or ordering, the hospital purchasing department should verify exact dimension compatibility (e.g. matching existing uterine manipulators or fornix cups in service).

Vaginal Tube & Vaginal Blocker Details

Choosing the Correct Vaginal Tube and Blocker

Before requesting a quotation, determine:

Vaginal tube, blocker or complete set
Tube outside diameter
Tube inside diameter
Overall and usable length
Straight or bevelled profile
Distal-rim configuration
Cap or plug requirement
Solid or inflatable blocker
Blocker outside diameter
Central-opening diameter
Compatible uterine manipulator
Material requirement
Reusable or single-use status
Sterile or non-sterile supply
Required quantity
Documentation and destination market
B2B Supply Channels

For Hospitals and Gynecology Centres

Hospitals may request:

Vaginal tubes in specified dimensions
Standalone vaginal blockers
Manipulator-compatible blockers
Tube-and-blocker sets
Replacement caps and seals
Multiple size requirements
Sterilisation trays
Biomedical compatibility review
Tender BOQ support
Vaginal Tube & Vaginal Blocker Details

For Medical Colleges

Medical colleges and teaching hospitals may request vaginal tube and blocker sets for authorised clinical use, simulation, demonstration or instrument familiarisation.

The intended environment should be clearly stated so the appropriate design, supply condition and documentation can be discussed.

B2B Supply Channels

For Dealers and Importers

Bharat Surgical accepts enquiries from:

Gynecology instrument dealers
Laparoscopic-equipment distributors
Hospital suppliers
Medical-device importers
Institutional tender suppliers
Export procurement companies

Dealers may request mixed sizes, bulk quantities, custom dimensional enquiries, export packaging and available technical documents. Destination-country regulatory and labelling requirements must be confirmed.

Vaginal Tube & Vaginal Blocker Details

Why Source Vaginal Tubes and Blockers from Bharat Surgical?

Tube, blocker and complete-set enquiries
Standard and custom dimensional requirements
Compatibility review for uterine-manipulator systems
Hospital and gynecology-centre supply
Dealer, distributor and importer support
Bulk and institutional procurement
Export-order assistance
Technical quotation based on verified requirements

All sizes, materials, configurations, reusable status, sterile supply and compatibility claims must be confirmed before final publication and supply.

Immediate Answers

Frequently Asked Questions

Find technical, reprocessing, ordering, and size compatibility answers for the Bharat Surgical Vaginal Tube & Vaginal Blocker range.

It is a tubular gynecology instrument designed for use as part of an authorised laparoscopic system.

It is a solid, inflatable or system-specific component that forms part of a compatible vaginal sealing arrangement.

No. They are different components, although they may be supplied as one set.

They appear in the supplied Bharat Surgical sitemap, but final models and specifications must be confirmed.

The current Bharat Surgical website does not publish verified sizes. Required dimensions should be submitted for quotation.

These dimensions appear in third-party market listings but have not been verified as Bharat Surgical’s available range.

Provide the outside diameter, inside diameter, overall length, usable length and distal profile.

Both profiles may exist in the market. Bharat Surgical’s available design must be confirmed.

It is a tube with an open central lumen. Its cap or sealing arrangement depends on the model.

Some designs include a removable cap or plug. Confirm the required configuration.

It is a non-inflatable blocker with model-specific dimensions and a possible central opening.

It is a blocker that incorporates a balloon and inflation channel according to its documented design.

No. Solid and other non-inflatable configurations may also exist.

Do not assume that an inflation accessory is included. Check the supplied-component list.

Only use the limit and method stated in the product-specific IFU. This page does not provide clinical instructions.

Some blockers are shaft-mounted or integrated into manipulator systems. Exact compatibility must be established.

No. Shaft diameter, position and locking mechanism may differ.

No. They are different instruments, although they may be used within a compatible gynecology system.

The terms may overlap, but the exact design, dimensions and interface must be checked.

The precise Bharat Surgical materials have not yet been verified and should be stated in the final quotation.

Some surgical tube instruments may use metal, while others use polymers or ceramic. Do not assume a material without documentation.

Some blockers may contain silicone, but Bharat Surgical’s exact material must be confirmed.

Latex-free status should be claimed only when supported by a material declaration.

Reusable and single-use configurations may exist. Confirm the selected product’s classification.

Not necessarily. Reusable status and sterile supply are separate specifications.

Only when their product-specific IFU validates steam sterilisation.

Only if the manufacturer validates the process for the balloon, valve and all other components.

Follow the IFU for disassembly, brushing the lumen, rinsing, drying, inspection and sterilisation.

Check the body, central opening, shaft connection, sealing surface and any balloon or valve.

Yes, subject to identifying the existing system and exact dimensions.

An individual tube may be quoted after its dimensions and design are confirmed.

Matching may be reviewed using measurements, photographs, drawings or a physical sample.

A custom dimensional requirement may be reviewed based on feasibility, quantity, validation and documentation.

Price depends on design, dimensions, materials, reusable status, accessories, quantity and documentation.

Dealers, distributors, importers and institutional suppliers may request bulk quotations.

Provide the tube and blocker dimensions, manipulator model, shaft diameter, required connection and clear photographs.

Export enquiries can be reviewed subject to destination-country registration, labelling and documentation requirements.

Medical and Procurement Disclaimer

This page provides general product and procurement information for qualified healthcare organisations and medical-device buyers. It is not a clinical or procedural instruction and does not replace professional training, clinical judgement, institutional protocols or product-specific instructions for use. Product dimensions, intended use, compatibility, materials, reprocessing, sterile supply and regulatory status must be verified before purchase and use.

Request a Quote for Vaginal Tubes and Vaginal Blockers

Contact Bharat Surgical with the required tube diameter and length, distal profile, blocker dimensions, solid or inflatable design, uterine-manipulator compatibility, quantity and delivery destination. For replacement products, provide measurements, drawings and clear photographs of the existing components.

Request Vaginal Tube and Blocker Price

Prices depend on: For an accurate quotation, send the required dimensions and system details.
Factors Affecting Price: Vaginal tube or blocker, Individual product or complete set, Diameter and length, Straight or bevelled design, Solid or inflatable blocker, Material, Reusable or single-use status, Cap, plug, adaptor and seals, Customisation, Quantity, Sterile packaging, Documentation, Delivery destination