ISO 13485:2016 Certified
40+ Years of Excellence
600+ Products
Download Catalog
MANUFACTURER & SUPPLIER | B2B UROLOGY INSTRUMENTS

Bi-TURP Set Manufacturer and Supplier in India

The Bi-TURP Set from Bharat Surgical is a configurable bipolar resectoscope system designed for transurethral electrosurgical procedures in urology. A complete set typically combines a telescope, inner and outer sheaths, obturator, bipolar working element, compatible electrodes and electrical connections for controlled resection and coagulation under endoscopic visualization.

Bharat Surgical manufactures TURP sheaths, bipolar electrodes and several active and passive working-element configurations. Because the company’s public catalogue does not provide one fixed Bi-TURP packing list, hospitals and distributors should obtain a component-wise quotation based on their telescope, generator and procedural requirements.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Bi-TURP Set surgical instrument on a clean clinical blue background
Overview

What Is a Bi-TURP Set?

A Bi-TURP Set—also called a Bipolar TURP Resectoscope Set—is an endoscopic instrument system used for selected transurethral urological procedures.

In a bipolar system, the electrosurgical circuit is completed locally between:

The active electrode or cutting loop
A return pole positioned within the electrode, resectoscope tip or sheath, depending on the system

This localized bipolar arrangement commonly permits the use of normal saline as the irrigation medium.

What Is Included in a Bi-TURP Set?

A complete Bi-TURP Set may contain:

Rigid telescope
Inner sheath and outer continuous-flow sheath
Obturator
Bipolar working element
Bipolar cutting loop, Collins knife electrode, ball electrode
Bipolar connecting cable, light-post adaptor, irrigation connectors
Stopcocks, cleaning adaptor, sterilization tray or protective box

This is a recommended quotation checklist—not a confirmed Bharat Surgical packing list. Every included component should be identified in the final commercial offer.

Specifications

Product Specifications and Confirmed Components

Product Specifications

SpecificationAvailable or Configurable Detail
Product nameBi-TURP Set
Alternate nameBipolar TURP Resectoscope Set
Product categoryEndourology and resectoscopy instruments
Energy systemBipolar
TelescopeDiameter, length and viewing angle to be confirmed
Sheath26 Fr Bharat Surgical model available
Sheath arrangementInner and outer continuous-flow configuration
Working elementBipolar active or passive configuration
Stem arrangementSingle or double stem according to system
Electrode optionsCutting loop, Collins knife and ball electrode
Irrigation mediumNormal saline commonly used; follow system IFU
Electrical cableGenerator-specific bipolar cable
GeneratorCompatible bipolar electrosurgical generator required
Main materialStainless steel with optical, insulating and sealing components
ReuseReusable metal and optical components expected; confirm each item
BrandBharat Surgical
Country of originIndia

Confirmed Bharat Surgical Components

Bharat Surgical currently lists the following relevant products:

Working Element Bi-TURP with extra monopolar fitting, active type
Working Element Double Stem Active & Passive
Working Element Single Stem Active & Passive
Working Element Passive for 4 mm system
TURP Inner and Outer Sheath, 26 Fr
Bipolar TURP cutting loop, Collins knife electrode, ball electrode
Monopolar TURP electrodes and resectoscope sets
TURP laser working element

These products indicate that Bharat Surgical can configure different TURP systems, but they should not all be assumed to be included in one Bi-TURP Set.

Applications

Clinical Applications and Bi-TURP vs Monopolar TURP

Clinical Applications

Depending on the supplied components, generator and approved instructions, a Bi-TURP Set may be considered for:

Bipolar transurethral resection of the prostate
Treatment of selected bladder-outlet obstruction associated with benign prostate enlargement
Transurethral incision using a compatible knife electrode
Coagulation during selected transurethral procedures
Bipolar tissue vaporization with an approved electrode
Selected bladder-tumour resection when the complete system is approved for that application
Other compatible endoscopic urology procedures

The final clinical application remains subject to the surgeon’s assessment and each component’s IFU.

Bi-TURP vs Monopolar TURP Set

Selection factorBi-TURP SetMonopolar TURP Set
Energy circuitCompleted locally within the resectoscope systemPasses through the patient to a return electrode
Irrigation mediumCommonly normal salineApproved non-conductive medium
Remote return padGenerally not part of the bipolar treatment circuitNormally required
Working elementBipolar-compatibleMonopolar-compatible
Electrode & cableBipolar loop/electrode and generator-specific cableMonopolar loop/electrode and generator-specific cable
Fluid concernSaline volume overload remains possibleHypotonic-fluid absorption and TUR syndrome are concerns
InterchangeabilityMust not be assumedMust not be assumed
Safety & Supply

Fluid Management, Safety Controls and B2B Supply

Why Normal Saline Is Used in Bipolar TURP

Normal saline is electrically conductive and is commonly used in bipolar transurethral systems because the current path is completed locally within the bipolar resectoscope arrangement. Compared with hypotonic, non-conductive media, saline avoids dilutional hyponatremia associated with classic TUR syndrome. However, excessive absorption can still cause volume overload, pulmonary oedema, cardiovascular stress, and hyperchloremic metabolic acidosis.

Preoperative Inspection: Inspect telescope, sheaths, locks, stopcocks, obturator, working element, electrodes, insulation, cable and generator connection.

Irrigation pressure, inflow, outflow, procedure duration and patient condition still require clinical monitoring.

Cleaning and Reprocessing

Disassemble components, pre-clean promptly, flush irrigation channels, clean lumens with compatible brushes, clean joints/locks, rinse thoroughly, dry completely, inspect, package, and sterilize using component-specific parameters.

B2B Supply & Information Required for Quotation

Bharat Surgical supplies configurable Bi-TURP Sets, bipolar working elements, 26 Fr sheaths, and replacement components to hospitals, urology departments, dealers, and export buyers.

When requesting a quotation, please provide:

Product name: Bi-TURP Set
Complete set or selected components / Bipolar-only or hybrid requirement
Telescope diameter, length and viewing angle
Sheath size (e.g., 26 Fr)
Active or passive working element and stem arrangement (single/double)
Required cutting loops, Collins knife or ball electrodes
Generator brand/model and bipolar cable reference
Sterilization tray requirement and required quantity
Delivery destination and regulatory/tender document needs
Immediate Answers

Frequently Asked Questions

Technical, component, compatibility and safety answers for the Bharat Surgical Bi-TURP Set range.

A Bi-TURP Set is a bipolar resectoscope system used for selected transurethral electrosurgical procedures in urology.

Yes. “Bi-TURP” is commonly used as a short form for bipolar transurethral resection of the prostate.

A complete set may include a telescope, inner and outer sheaths, obturator, bipolar working element, electrodes and cable. The exact Bharat Surgical packing list must be confirmed.

Yes. Bharat Surgical lists a 26 Fr stainless-steel inner and outer TURP sheath.

It should not be assumed. Request written confirmation of the telescope diameter, angle, length and inclusion.

Bharat Surgical lists bipolar cutting loops, Collins knife electrodes and ball electrodes.

Bipolar TURP systems commonly use normal saline, subject to the electrode, generator and resectoscope instructions.

No. Excessive absorption can still cause volume overload and cardiopulmonary or acid–base complications.

A dedicated bipolar circuit generally completes current locally. Follow the generator instructions, particularly if other monopolar equipment is also used.

No. The generator must support the required bipolar TURP mode and connector system.

Cable inclusion is not confirmed. It should be separately listed in the quotation.

It is a working element whose manual and spring action move the electrode according to an active-system mechanism.

It uses a different manual and spring-return action. The electrode must match the passive mechanism.

Not automatically. Length, stem, movement and connector compatibility must be verified.

It is a configurable working element that may include an additional fitting for approved monopolar accessories. Exact compatibility must be confirmed.

No assumption should be made. Conventional monopolar systems require an approved non-conductive fluid, while bipolar TURP commonly uses saline.

Only if the complete system and supplied components are approved for that procedure and the surgeon determines it is appropriate.

The sheaths, working element and telescope are generally reusable system components. Each electrode and accessory must be individually confirmed.

Follow the component-specific IFUs. The telescope, seals, electrodes and stainless-steel parts may have different processing requirements.

Inspect the telescope, sheaths, locks, stopcocks, obturator, working element, electrodes, insulation, cable and generator connection.

Medical and Procurement Disclaimer: Component lists, telescope specifications, electrode quantities, compatibility, pricing, lead time and certifications must be confirmed through current Bharat Surgical documentation. Next Level 4 page: URS Handle.

Request a Complete Set Quote for Bi-TURP

Contact Bharat Surgical for complete bipolar TURP resectoscope sets, 26 Fr inner and outer sheaths, active or passive working elements, single-stem and double-stem systems, hybrid bipolar-monopolar working elements, bipolar cutting loops, Collins knife and ball electrodes, hospital procurement, dealer/distributor supply, bulk orders, export requirements, and tender enquiries.